Meaning
A specimen is the test piece a property is measured on, made to the size, thickness and preparation the test method sets. Every value on a casting resin sheet belongs to a specimen of that kind. A cast part matches the printed value only as far as it matches the specimen. Its thickness, cure and conditioning are therefore part of the figure.Thickness Range
The specimens behind the figures in these resources span a wide range of thickness. Sika’s UL 94 rating for PX331 rests on 3 mm (0.118 in), and its aviation line on 1.5 mm (0.059 in). PX523’s dielectric strength rests on 1 mm (0.039 in). On Renishaw’s sheets, heat deflection uses a 6.4 mm (0.25 in) bar. Shrinkage bars run from 3 mm to 5 mm (0.12 in to 0.20 in). Walls thinner than the specimen fall outside what its figure says.Read More
Bar Shapes
The Renishaw heat deflection bar is 110 × 12.7 × 6.4 mm (4.33 × 0.50 × 0.25 in). Sika’s sheets give ISO 75A values and name no bar. A shrinkage bar is long and flat on purpose, so the loss is easy to read and the cure stays even. ASTM D648 applies to material 3 mm (0.12 in) or thicker and allows a cemented stack for thinner sheet. ISO 527-1 sets specimen types suited to different materials for tensile tests.Preparation and Cure
A specimen carries the cure it was given, and the sheets name it in footnotes. ISO 75-2 notes that some materials need annealing of the specimens, which generally raises the result. A post-cured cast specimen behaves the same way. A part delivered without the cure in the footnote is not the specimen of the table.Specimen Conditioning
Specimens are conditioned before they are tested. ISO 291 sets standard atmospheres for all types of plastics test specimen. UL 94 conditions its vertical bars for 2 days at 23 °C (73 °F) and 50 % relative humidity. Its other conditioning is 7 days at 70 °C (158 °F) in an oven. Whether rated bars and delivered parts share a conditioning history is seldom stated.Part Difference
A real part differs from a bar in 3 ways the bar hides. A feature around a core cannot shrink freely, a thick section cures hotter, and flow direction changes the result. A 2004 dissertation measured a cast specimen in 8 dimensions with a micrometer reading to 10 µm (0.0004 in). Its losses ranged from 0.29 % to 1.55 % within the one specimen.Buyer Questions
A buyer working from a sheet asks which specimen produced each figure. The answer names the size, the thickness, the cure and the conditioning. It also says whether the value is measured or typical. Where the part’s wall is thinner than the specimen, a test on the part itself is the direct answer.