Meaning
Measurement is the reading of a cast part’s size, surface or property under stated conditions, so that 2 readings of the same part can agree. For cast polyurethane the stage, the temperature and the support of the part all move the result. A number without those conditions is hard to compare with anything. A measuring note on the drawing removes a common source of argument at the cost of one line.Stage of the Reading
A part can be read as cast or after its post-cure, and the 2 readings differ. Dimensions shift between the as-cast and post-cured states. The rule is to measure at the same stage every time, after cooling. The same part gives different readings warm or cold, free or held, before or after post-cure. Both numbers are correct for their own conditions.Read More
Temperature of the Reading
A part fresh from a 100 °C (212 °F) oven has not reached the state it will have a day later. ISO 291 defines the conditioning atmospheres used before plastics are tested. ISO 1 fixes a standard reference temperature for dimensional properties. A shrinkage figure is comparable only between parts measured at the same temperature. Measured hot at demold, a part reads larger than after a night in the inspection room.Instrument and Method
A 2020 study read its cast covers on a profile projector, an optical comparator. It read roughness with a stylus at 0.5 mm/s (0.02 in/s) and a cut-off of 0.25 mm (0.0098 in). The study gave no measurement uncertainty for either. A 2004 dissertation used a micrometer reading to 10 µm (0.0004 in), with 10 readings per dimension around each specimen. A tensile figure is read against the method that produced it, such as ISO 527-1.Support State
Whether the part is measured free or held in a fixture is part of the reading. A thin or long cast part can deflect under its own weight on a bench. The buyer sets the stage, the cooling and conditioning time and the support state. Writing all three into the specification lets a later batch be read the same way.Sample Size
A few copies say little about a whole tool. The 2020 study measured 3 copies per series, which cannot show how a mold behaves across 20 or 50 copies. Measuring the first and the last copy of each tool on a named feature turns a copy count into a measurement.Optical Measurement
A clear part needs its optical figures measured on a cast sample. The 89 % light transmission on PX522’s sheet names no thickness, wavelength or surface finish. A buyer who needs a defined transmission or haze asks for it at a stated thickness. It is taken on the production grade, after its real cure.