A set of test bars, two touches of a 20 mm flame lasting 10 seconds each, and not one bar allowed to keep burning for more than 10 seconds after the flame is taken away. That is what a V-0 result means in the UL 94 vertical test, and every data sheet that prints the three characters V-0 is summarizing it. The sheet for SikaBiresin PX331 prints V-0 at 3 mm, and Renishaw’s sheet for resin 8263 prints UL94V-0 without a thickness.
A flame rating decides whether a cast housing can go into an enclosure program, and it is also among the easiest claims to overread. This piece reads the standards behind the rating, tabulates the classes, shows what the two flame-retardant casting resins in these resources’ sources actually print, and lists what the rating leaves open.
How UL 94 Rates a Cast Resin Bar
UL 94 is a family of small-scale burning tests for plastic materials, not a single test. UL’s own description lists twelve flame classifications. Six of them apply to enclosure and structural parts, namely 5VA, 5VB, V-0, V-1, V-2 and HB, three apply to low-density foam, and three, VTM-0 to VTM-2, apply to thin films usually found on flexible printed circuit boards. A casting resin for housings belongs to the first group.
The tests differ in how the sample is held and how large the flame is. HB is a horizontal burning test that measures how fast the flame travels. The V tests hold the bar vertically and use a 50 W flame 20 mm high, and the 5V tests use a 500 W flame and a 125 mm flame height, which UL describes as approximately five times more severe than the flame in the V tests.
UL 94 ranks materials by how they behave in a small flame at a stated thickness. It does not describe how a finished product burns in a fire.
The standards that mirror the test are named on UL’s page. HB corresponds to IEC and DIN EN 60695-11-10 method A, and V corresponds to method B of the same document, available on request. ASTM D3801 states that its vertical-burning test method and the 20 mm (50 W) vertical test of ANSI/UL 94 for the V-0, V-1 and V-2 classes are equivalent. These cross references let a buyer in Europe and a buyer in North America read the same word on two sheets, but they do not move a rating from one thickness to another.
The Classes a Casting Sheet Can Print
UL 94 sorts solid plastics into six classes, from HB, a slow horizontal burn, through V-2, V-1 and V-0 in the vertical test, to 5VB and 5VA under a flame about five times larger. Only V-0 appears on the casting sheets opened for these resources, and a 5V class appears once in a brochure.
For a cast resin, V-0 is a demanding line: every bar stops flaming within 10 seconds of each touch, the set stays within 50 seconds in total, and nothing drips alight. A cast bar can sit close to that line, because its properties depend on a mix and a cure made for each batch, so the margin a maker’s bars show is a margin for the maker’s own batch.
A casting house therefore treats a V-0 claim as a property of a resin used exactly as its sheet prescribes, with the stated mix ratio, pigment loading and oven cure, and it records those three for each batch that goes into a flame-rated part. A batch mixed off ratio or cured short is a different material for the purpose of the rating, even when it looks the same.
Where HB Fits
HB sits below the V classes, and UL calculates it from the burning rate and the thickness of the specimen. The limit is a burning rate of 40 mm/min or less for specimens 3 to 13 mm thick and 75 mm/min or less for specimens under 3 mm, or a flame that goes out before the first mark. That wide gap hints at how much the standards let thickness change the result.
ASTM D635 is the horizontal small-scale method on the American side. It covers comparing the linear rate of burning or the extent and time of burning of plastic bars tested in a horizontal position, and it states that correlation with flammability under actual use conditions is not implied.
Mold, Pigment and Wall Thickness Behind One Rating
A rating always belongs to a material at a thickness, and the sheets that omit the thickness leave the reader to ask for it. ASTM D635 puts the reason in its significance section: the rate of burning and other burning phenomena are affected by factors such as density, pigments, any anisotropy of the material and the thickness of the specimen, and test data should be compared only for specimens of similar thickness.
That sentence deserves a slow read for a cast polyurethane part.
Density changes between grades, since the cured resins here run from about 1.06 to 1.35 g/cm³ (66 to 84 lb/ft³) on their sheets. Pigment is added at 1 percent by weight in the polyol on Sika’s PX331, and up to 2 percent of total weight on Renishaw’s 8263. Thickness, finally, is a design choice. Each of these three can differ between the test bar a maker burned and the housing a buyer draws.
Two questions come out of that:
- Was the rating measured on a natural or a pigmented bar, and does the pigment on the drawing match it?
- Is the thinnest wall on the part at or above the thickness of the rated bar?
An Example From Two Thicknesses
Sika’s sheet for PX331 gives its flame data at two thicknesses in one block.
The UL 94 rating is V-0 at 3 mm (0.118 in), and the EN 60695-11-10 result is also V-0 at 3 mm. Compliance with the FAR 25 §853 (b) aviation fire standard is listed at 1.5 mm (0.059 in). Read side by side, the three lines show that a maker states the thickness each time, and that the thinner wall is tied to a different document and a different test. A buyer cannot carry the V-0 down to 1.5 mm, since the sheet does not claim it.
What the Vertical Test Asks of a Cast Bar
A rated casting resin was mixed and cured into bars before it was burned, so every bar in the set is itself a small casting. The flame touches each upright bar twice for 10 seconds, and the criteria ask how long it burned after each touch, how long the sum runs over the whole set, how long it glows, and whether anything drips alight onto the cotton below.
The limits are per bar and in total, and the total is the one a quick read misses. One bar that burns for 12 seconds after a flame application fails V-0 by itself.
A set that gives 6 seconds of burning after every one of its flame applications can still fail once the set is large enough, because the set is judged on a total of 50 seconds or less and each bar takes two applications. Each individual burn then sits well under the 10-second limit, and the sum does not. The test is short and unforgiving at the margin. A casting run with a loose mix ratio, a wet pigment or an under-cured bar is a different bar from the one the maker burned, and a cast part made the same way can read differently from the sheet. That is why the questions further down ask for the cure and pigment of the test bars, and not only the class.
Tracking Resistance Is a Different Property
A buyer looking at an electrical enclosure meets two numbers that sound alike. One is the flame rating, and the other is tracking resistance, which PX523 prints as 600 V under IEC 60112 E3 on its clear grade, and which describes how a surface withstands electrical leakage across it. UL calls the ignition-resistance and surface-tracking characteristics of plastics a separate matter, covered by UL 746A, which it describes as similar to IEC 60112, 60695 and 60950.
The two properties travel on different pages of a sheet and answer different questions. A flame-retardant resin can have an unremarkable tracking value, and a resin with a tracking value on its sheet can carry no flame rating, which is the case for PX523, whose sheet prints no flame statement. An enclosure program lists both, with the test method and the thickness next to each.
Flame Statements on the Casting Sheets
Among the sheets opened for these resources, two resins carry a flame statement. The others, including PX205, PX522, PX523, PX 223 HT, 6230 and 8020-2, print no flame rating at all.
| Resin | Statement on the sheet | Thickness stated | Method named |
|---|---|---|---|
| SikaBiresin PX331 | UL 94 flammability rating V-0 | 3 mm (0.118 in) | UL 94 |
| SikaBiresin PX331 | V-0 under NF EN 60695-11-10, described on the sheet as a glow-wire test | 3 mm | NF EN 60695-11-10 |
| SikaBiresin PX331 | compliant with the FAR 25 §853 (b) aviation fire standard | 1.5 mm (0.059 in) | FAR 25 §853 (b) |
| Renishaw 8263 | certified fire retardant UL94V-0, suitable for electrical enclosures | not on the sheet | UL 94 |
Two things stand out in the table. Sika’s sheet calls the EN 60695-11-10 result a glow-wire test, while the scope of IEC 60695-11-10 describes small-scale tests with a small flame of nominal power 50 W, one horizontal for burning rate and one vertical for self-extinguishing. Those two descriptions do not match, and a buyer who needs a glow-wire result asks Sika which test was run, since glow-wire testing is a separate family of tests that these pages do not describe.
The Renishaw brochure adds a second wrinkle. It lists resin 8263 as UL94 V=0 5 V flame-retardant, a phrase that reads as V-0 and 5V together, while the sheet for the same resin states UL94 V-0 only. Both documents come from one maker and were issued years apart, and a 5V claim would need a rating that appears nowhere on the sheet. Reading the sheet is the conservative choice, and anyone who wants 5V on a part asks for the listing.
Who Holds the Rating and What a Casting House Can Sign
The rating belongs to a material from a maker, tested as that maker prepared it. A casting house that pours the resin into a silicone mold at 70 °C and cures it as the sheet prescribes is producing a part from that material, and the rating on the sheet is the most it can point to. It cannot extend the rating to a thinner wall, a different pigment loading or a post-cure the maker did not test.
| Question | A usable answer names | Seen on the opened sheets |
|---|---|---|
| Which test produced the rating? | UL 94 vertical, or a named equivalent such as IEC 60695-11-10 method B | PX331 names UL 94 and NF EN 60695-11-10 |
| At what thickness? | a figure in millimeters | 3 mm for PX331; none on the 8263 sheet |
| In which color or pigment condition? | natural, or a named pigment at a stated loading | not stated on either sheet |
| After which cure? | the oven and post-cure schedule of the test bars | not stated |
| Who issued the listing? | the maker, a test laboratory or a directory entry | 8263 says certified, without a listing number |
The table is a tool for the quote stage, and the last column shows how many of its answers the two sheets leave out. None of that is a fault in the sheets, which are written to guide a user of the resin, and the buyer closes the gaps by asking.
What a supplier can reasonably put in a quote, using only what the opened documents support, is a short list:
- the resin and the maker’s sheet it names, with the rating as the sheet prints it;
- the thickness at which the sheet states the rating;
- the color or pigment condition, if the sheet states one, and a statement when it does not;
- a plain note that the figure is a material rating and not a test of the finished part.
A flame rating is a property of a material at a thickness and a color. The part inherits it only when the part matches the tested bar.
Limits of a Small-Flame Rating
The vertical test method in ASTM D3801 reports afterflame and afterglow time in seconds for a material of specified shape, and it states that its results are valid only for the fire-test-exposure conditions it describes, because different conditions will likely change the fire-test response. A rating is a statement about one setup, repeated carefully.
ASTM D3801 is blunt about its purpose: the standard was developed for polymeric materials used for parts in devices and appliances, and its results are meant as a preliminary indication of acceptability. Final acceptance depends on the complete equipment and the standard that applies to it. The standard also states that it does not cover plastics used for building construction, finishing or contents such as wall and floor coverings, and that it does not evaluate fire resistance in hours, flame spread, smoke or heat release.
ASTM D635 adds a caution that applies to the whole family of burning tests. Such tests fix certain variables arbitrarily, such as specimen size, energy source, application time and end points, and some materials turn out to be unusually sensitive to one or more of them, which leads to highly variable results. The standard says that additional characterization by other methods is highly desirable in such cases. For a cast thermoset, a rating at the margin of a pass limit, say a total burning time of 48 seconds against a limit of 50, calls for a second look at the lot and the cure before anyone calls the material compliant.
Several things follow for a buyer of cast parts:
- A V-0 resin does not make a housing compliant with an equipment standard, because that standard tests the assembled product.
- Smoke, flame spread and heat release are outside the test, so a program with such requirements asks for separate evidence.
- The 7 days at 70 °C of conditioning in the V tests is an aging step, and the sheets do not say whether the bars were conditioned the same way as the part will be at delivery.
For flame-retardant parts in dozens to a few hundred copies, low-volume vacuum casting keeps the same resin, color and wall thickness through the run, and the same discipline carries into bridge production when a program moves toward a hard tool. The rating does not travel with the drawing, though. A housing that is later injection molded is made from a thermoplastic with its own rating at its own thickness, so the cast part’s V-0 says nothing about the molded one, and the flame evidence is gathered again for the molding resin.
Sources and Further Reading
- UL Solutions, Combustion fire tests for plastics, UL 94 flame ratings
- ASTM International, D3801, standard test method for measuring the comparative burning characteristics of solid plastics in a vertical position, scope
- ASTM International, D635, standard test method for rate of burning and extent and time of burning of plastics in a horizontal position, scope
- Estonian Centre for Standardisation and Accreditation, EVS-EN 60695-11-10:2013, test flames, 50 W horizontal and vertical flame test methods, scope
- Sika, SikaBiresin PX331, product data sheet, version 01.01, 08-2026
- Sika, SikaBiresin PX523, product data sheet, version 02.01, 11-2026
- Renishaw, Data sheet: vacuum casting resin 8263, issued 05.2015
- Renishaw, Brochure: vacuum casting systems, issued 10.2017