Thermomechanical Analysis Method

The thermomechanical analysis method, or TMA, tracks a small solid specimen's length as it heats, to find its expansion and glass transition.

Every Thermomechanical Analysis Method article of the Vacuum Casting Resources, newest first, each written from published standards, research and makers’ data.

Meaning

The thermomechanical analysis method, or TMA, tracks a small solid specimen’s length as it heats, to find its expansion and glass transition. ISO 11359-2 describes it for plastics. Casting sheets use it for glass transition values, and Renishaw’s 6230 sheet names it outright. It works without the bending load of a heat deflection test.

TMA-Measured Grades

Renishaw gives the glass transition of 6230 as 115 °C (239 °F) by thermomechanical analysis. Sika gives PX 223 HT a glass transition of 120 °C (248 °F) by TMA under ASTM E1545. PX331’s glass transition is listed under ISO 11359, which is related to 6230’s TMA figure by method. ASTM E1545 may give a value a few degrees away on the same resin.
Read More

Heat Deflection Difference

TMA does not load the specimen in bending. Its heating regime also differs from the ISO 75 test. The 2 softening points of one resin therefore need not agree. Their difference is not a safety margin.

Expansion Measurement

Thermomechanical analysis also gives the coefficient of linear thermal expansion. PX 223 HT prints 115 ppm/°C (64 ppm/°F) under ISO 11359-2. That figure lets the contraction of a part cooling from the mold be estimated.

Sheet Comparison

The ABS-like sheets list glass transition under ISO 11359, under a TMA method and under ASTM E1545. Heat figures compare reliably only inside one maker’s own sheets. A buyer comparing grades across makers asks for the method behind each value.

Single-Sheet Example

Renishaw’s 6230 sheet shows both methods side by side. It gives a glass transition of 115 °C (239 °F) by TMA. Its heat deflection is 98 °C (208 °F) at 1.80 MPa (261 psi). The 17 °C (31 °F) between them describes 2 test setups, and neither is a service limit.

Demolding and Post-Curing Vacuum Cast Parts

Each grade prints its own demold time and its own post-cure, and thin or long parts are supported in the oven while it runs.

Demolding Vacuum Cast Parts at 70 °CDemolding means opening the silicone tool and taking the copy out once the resin has gelled and hardened far enough to hold its form. In every sheet on file the tool stays at 70 °C (158 °F) in the oven for that time.

Heat Deflection Temperature of Cast Polyurethane Under ISO 75 and ASTM D648

Heat deflection temperature ranks materials under one loaded test and does not set a service ceiling, so it is read together with post-cure and part geometry.

Heat Deflection as One Loaded Bar TestThe test bends a bar under a fixed load while the temperature climbs, and it records the temperature at which the bar has deflected by a set amount. ISO 75-1 describes the general method for determining the temperature of deflection under load, with flexural stress applied in three-point loading.

ABS-Like Polyurethane Casting Resins for Vacuum Casting

An ABS-like polyurethane resin is a stiff thermoset named for its use, and its datasheet numbers depend on post-cure, thickness and test method.

Why a Polyurethane Resin Is Called ABS-LikeThe phrase is a maker's shorthand, not a standard. Sika describes its SikaBiresin PX331 as having mechanical properties similar to thermoplastics like filled ABS, and Renishaw lists its 6230 as having properties similar to ABS.